Schneider Electric iC60H2 C16
Pris exklusive moms
Skriv ut
INFO
Produktgrupp
Elektronik
Märke / modell
Schneider Electric iC60H2 C16
Uppställningsplats
Jõhvi
Land
Estland
Mascus ID
D32E7E8C
PRIS
Jämför i annan valuta
DETALJER
Lagerid
DY48120
Reservdels ID
iC60H2 RCBO, C16, IEC 61009-1, CS30323, EN61009-1, F-92506, 2500866930, A9D19232
Annan information
Unused, without packing Schneider RCBO Ic60H2 Double Pole Curve C Type A 32A 110V Overcurrent Protect
A9iC60H2 2P 32A C 30mA 110v RCBO
· This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO).
· It is a 2P circuit breaker with 1 protected pole and 32A In rated current and C tripping curve.
· The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous.
· The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard.
· Its unique Visitrip indicator reduces intervention time by showing the faulty circuit.
· Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance.
· Its fast closing mechanism independent of manual operation improves its service life.
· This product is compliant with IEC 61009-1 and AS/NZS 61009.1 standard.
· It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles.
· The Ue operational voltage is 110VAC.
Schneider RCBO Ic60H2 Double Pole Curve C Type A 32A 110V Overcurrent Protect
A9iC60H2 2P 32A C 30mA 110v RCBO
· This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO).
· It is a 2P circuit breaker with 1 protected pole and 32A In rated current and C tripping curve.
· The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous.
· The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard.
· Its unique Visitrip indicator reduces intervention time by showing the faulty circuit.
· Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance.
· Its fast closing mechanism independent of manual operation improves its service life.
· This product is compliant with IEC 61009-1 and AS/NZS 61009.1 standard.
· It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles.
· The Ue operational voltage is 110VAC.
Schneider RCBO Ic60H2 Double Pole Curve C Type A 32A 110V Overcurrent Protect
A9iC60H2 2P 32A C 30mA 110v RCBO
· This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO).
· It is a 2P circuit breaker with 1 protected pole and 32A In rated current and C tripping curve.
· The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous.
· The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard.
· Its unique Visitrip indicator reduces intervention time by showing the faulty circuit.
· Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance.
· Its fast closing mechanism independent of manual operation improves its service life.
· This product is compliant with IEC 61009-1 and AS/NZS 61009.1 standard.
· It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles.
· The Ue operational voltage is 110VAC.
Original catalog number: iC60H2 RCBO, C16, IEC 61009-1, CS30323, EN61009-1, F-92506, 2500866930, A9D19232